Facade Systems
Concealed Fastener Rainscreen System
System Depth = 3” + Continuous Insulation (2" to 5" thick as indicated on drawings)
Joint Width = 3/8”
 
System Components:
P1. EQUITONE Panel
E1. Universe Hanger Rail Extrusion - Black Color
E2. Universe Sill Rail Extrusion - Black Color
E3. Universe Vertical Rail Extrusion
E4. Universe Tie-Back Rail Extrusion (As required)
E5. Universe Tie-Back Bracket (As required)
E6. Universe Hanger Rail Splice - Black Color
E7. Universe Starter Rail Extrusion - Black Color
E8. Universe Terminator Rail Extrusion - Black Color
A1. Concealed Anchor
F1. Extrusion Fastener
F2. Rail Fastener
S1. 1/4" Thermal Isolators
X1. Continuous Insulation Vertical Wide-Faced Hat Framing
X2. Wide-Face Hat Framing Fastener; attaches through mineral wool to substrate
X3. Roxul® ComfortBoard™ CIS 11# Density Mineral Wool Insulation
X4. Air and Moisture Barrier
X5. Sheathing
X6. 16 Gauge Min. Steel Stud
 
Notes:
•    Horizontally attached across framing.
•    Panels that are 5'-0" or taller must include a shop attached tie-back stiffener with the tie-back rail shipped loose.
•    Extrusions have splices for support between studs.
•    Insulation (X3) must be mineral wool. Foam plastic insulation triggers NFPA-285 fire code which requires a tested assembly.
 
 