Facade Systems
Concealed Fastener Rainscreen System
System Depth = 1 1/2”
Joint Width = 3/8”
 
System Components:
1.    Trespa®  Meteon® Panel
2.    Universe Hanger Rail Extrusion – Black Color (Shop Attached)
3.    Universe Intermediate Rail Extrusion
4.    Extrusion Fastener
5.    Fixed Bracket (Shop Attached)
6.    (2) 1/4” Thermal Isolators
7.    Air & Moisture Barrier
8.    Sheathing
9.    16 Gauge Min. Steel Stud
 
Notes:
•    Horizontally attached across framing.
•    Thermal Isolators (6) are required at each Fixed Bracket Clip (5).
•    Air & Moisture barrier (7) must be VaproShield® WallShield®, WrapShield®, RevealShield™, Cosella-Dorken Delta® Fassade-S, Delta® Foxx, Delta® Foxx-S, Tyvek® CommercialWrap®, Dow Corning DefendAir 200 or Momentive™ SEC2500-SilShield AWB.
•    Extrusions have ventilation slotting and splices for support between studs.
•    Available with 10mm and 13mm Trespa Meteon (1) panel thickness only.