Facade Systems
*Details showing this system are not available at this time.
Exposed Fastener Rainscreen System
System Depth = Varies
Joint Width = 3/8”
 
System Components:
1.    Trespa®  Meteon® Panel
2.    Panel Fastener
3.    Adjustable Angle Bracket
4.    Adjustable Angle Fastener
5.    Universe Adjustable Angle Extrusion – Black Color
6.    Adjustable Angle Extrusion Fastener
7.    Thermal Isolator #1
8.    Thermal Isolator #2
9.    Mineral Wool Insulation
10.    Air & Moisture Barrier
11.    CMU
 
Notes:
•    Vertically attached. Vertical Adjustable Framing (3-6) and Studs (12) must align with Panel Fasteners (2), otherwise additional framing will be required.
•    The Adjustable Angle Extrusion (5) adjacent to the panels will need to be painted black.
•    Insulation (9) must be mineral wool. Foam plastic insulation triggers NFPA-285 fire code which requires a tested assembly.  The only other option is to acquire an AHJ approval. Receiving an AHJ approval is not guaranteed. 
•    Air & Moisture barrier (10) must be VaproShield® WallShield®, WrapShield®, RevealShield™, Cosella-Dorken Delta® Fassade-S, Delta® Foxx, Delta® Foxx-S, Tyvek® CommercialWrap®, Dow Corning DefendAir 200 or Momentive™ SEC2500-SilShield AWB if mineral wool (9) is less than 2” thick; if mineral wool is thicker than 2” then other barriers may be used.
•    Painted and decorative panel fasteners (5) are available for a premium.