Facade Systems
Concealed Fastener Rainscreen System
System Depth = 1 1/4” +  Universe Continuous Insulation System (1” to 3” thick as indicated on drawings)
Joint Width = 3/8”
 
System Components:
1.    Trespa® Meteon® Panel
2.    Universe Aluminum Rail – Black Color
3.    Fixed Bracket (Shop Attached)
4.    Adjustable Bracket (Shop Attached)
5.    Continuous Insulation Vertical Wide-Faced Hat Extrusion Framing
6.    Wide-Face Hat Framing Fastener; attaches through mineral wool to substrate
7.    Roxul® ComfortBoard™ CIS 11# Density Mineral Wool Insulation
8.    Air & Moisture Barrier
9.    CMU
 
Notes:
•    Insulation (7) must be Roxul® ComfortBoard™ CIS 11# Density mineral wool in order to be NFPA-285 fire code compliant and provide the required rigidity for the framing to attach against. Foam plastic insulation triggers NFPA-285 fire code which requires a tested assembly.
•    Air & Moisture barrier (10) must be VaproShield® WallShield®, WrapShield®, RevealShield™, Cosella-Dorken Delta® Fassade-S, Delta® Foxx, Delta® Foxx-S, Tyvek® CommercialWrap®, Dow Corning DefendAir 200 or Momentive™ SEC2500-SilShield AWB if mineral wool is less than 2” thick; if mineral wool is thicker than 2” then other barriers may be used.
•    Available with 10mm and 13mm Trespa Meteon (1) panel thickness only.
•    The framing (5) is not painted.